The submitted paper deals with ultrawidernband PD probing of HV cable terminationsrnin service. Under noisy on-site condition a PDrndetection sensitivity as low as few Pc could bernachieved. Using advanced digital signalrnprocessing, the stored PD data were analysedrncycle-by-cycle, after the on-site tests have beenrnfinished. Due to this method a large number ofrnterminations could be inspected within arncomparatively short time. The PD patternsrnobtained in the UHF range are well comparablernwith those, obtained by the conventional IECrnmethod. Hence, for identification the recognisedrnPD events existing knowledge on PD patternrnrecognition could be used.
机译:提交的论文涉及服务中的HV电缆终端的超宽带PD探测。在嘈杂的现场条件下,可以实现低至Pc的PDrn检测灵敏度。在完成现场测试后,使用先进的数字信号处理技术,逐周期分析存储的PD数据。由于这种方法,可以在相对短的时间内检查大量的终止。在UHF范围内获得的PD模式与通过常规IEC方法获得的PD模式非常相似。因此,为了识别所识别的PD事件,可以使用关于PD模式识别的现有知识。