AN INTEGRATED APPROACH TO ASSESS THE BIODEGRADABILITY OF A WASTEWATER CONTAINING CHROMIUM BY USING CHEMICAL AND BIOLOGICAL METHODS

机译:化学与生物方法综合评价含铬废水生物降解性的综合方法

获取原文
获取原文并翻译 | 示例

摘要

The Aguas do Norte Alentejano (Water and Wastewater Service Company belonging to the Aguas de Portugal Company) has decided to implement a treatment plant to treat an urban wastewater with a significant influence of tannery effluents. The design of the wastewater treatment plant was attributed to a consortium coordinated by Sisaqua Company. Since the levels of the biodegradability and toxicity of the wastewater to be treated were unknown, Sisaqua Company asked the UBiA/New University of Lisboa to develop and execute a monitoring plan to define the chemical composition and the levels of the biodegradability and toxicity of the wastewater. A composite sampling procedure of the wastewater was performed during a daily working cycle of the tanneries. The composite sample was characterized for 19 chemical parameters. Five of those parameters were total Cr, Cr (Ⅵ), Zn, Cu and Al, which were determined in the dissolved and suspended fractions. The composite sample was also submitted to a biological test to assess its degree of biodegradability. This assay was performed according to the methodology referred in the test 301E of OECD [1], taking into account its amendment of 1992. A respirometric assay was carried out to assess the toxic effect of the composite sample on the biological populations involved in the biological oxidation of organic compounds. This assay followed the "Sapromat" methodology developed by Brabander and Vandeputte [2]. Finally, the composite sample was submitted to a coagulation-flocculation process, according to the methodologies proposed by Eckenfelder [3, 4] and Pereira [5]. The supernatants were characterized for the same parameters as it was previously described for the composite sample. It was possible to conclude that the high levels of Cr present in the composite wastewater were mainly in the trivalent oxidation state. Since this oxidation state is less toxic for biological populations than the Cr (Ⅵ) and this metal was mainly in the suspended fraction, it was possible to obtain a biodegradability degree of the organic compounds quite similar to those observed for domestic wastewaters. The toxicity determined by the "Sapromat" method was slightly higher than those determined for domestic wastewaters. Nevertheless, this toxicity level did not affect significantly the wastewater biodegradability. The Cr (Ⅲ) was easily removed by a chemical coagulation-flocculation process.
机译:Aguas do Norte Alentejano(葡萄牙阿瓜斯公司的水和废水服务公司)已决定建立一个污水处理厂,以处理对制革厂废水有重大影响的城市废水。废水处理厂的设计归功于Sisaqua公司协调的一个财团。由于未知待处理废水的生物降解性和毒性水平,因此Sisaqua公司要求UBiA /新里斯本大学制定并执行监测计划,以定义废水的化学成分以及生物降解性和毒性水平。在制革厂的日常工作周期中,对废水进行了复合采样程序。对复合样品的19个化学参数进行了表征。这些参数中的五个是总Cr,Cr(Ⅵ),Zn,Cu和Al,它们是在溶解和悬浮部分中测定的。还将复合样品进行生物测试以评估其生物降解程度。考虑到1992年的修正,根据OECD 301E检验[1]中引用的方法进行了该测定。进行了呼吸测定,以评估复合样品对涉及生物学的生物种群的毒性作用。有机化合物的氧化。该测定法遵循Brabander和Vandeputte [2]开发的“ Sapromat”方法。最后,根据Eckenfelder [3,4]和Pereira [5]提出的方法,将复合样品进行混凝-絮凝处理。表征上清液的参数与先前针对复合样品所述的参数相同。可以得出结论,复合废水中存在的高含量的Cr主要处于三价氧化态。由于该氧化态对生物种群的毒性小于Cr(Ⅵ),并且该金属主要在悬浮部分中,因此有机化合物的生物降解度可能与在生活废水中观察到的相似。通过“ Sapromat”方法测定的毒性略高于对生活废水测定的毒性。然而,该毒性水平并未显着影响废水的生物降解性。 Cr(Ⅲ)易于通过化学混凝-絮凝工艺去除。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号