Experiences in using laser Doppler vibrometers at Chernobyl Nuclear Power Plant

机译:切尔诺贝利核电站使用激光多普勒测振仪的经验

获取原文
获取原文并翻译 | 示例

摘要

The implementation of laser vibrometers into various branches of industry solves complex technical problems as well as raising the authority of laser vibrometry as unique measurement tool. From this point of view, the nuclear industry is an interesting and attractive application field with specific and rigorous exploitation conditions of measuring systems.. The objective of this work was to evaluate all advantages and disadvantages of the laser Doppler vibrometry with respect to nuclear power plant (NPP) equipment examination. The Chernobyl NPP is the ideal place for these purposes. The diagnostic ability on different Chernobyl NPP systems (e.g. third power unit main circulators, bearing shaft of fifth turbogenerator and various pipelines) has been demonstrated using laser Doppler vibrometers. The measurements performed by laser vibrometers were checked by standard Chernobyl NPP vibration measurement tools. The laser Doppler vibrometers (CLV, Polytec GmbH and LDV, Kiev University) have been tested and have shown full functionality in NPP zone at 0.5 sievert/hour radiation levels, high electromagnetic fields (magnetic component up to 5 kA/m) and significant vibrations.
机译:将激光测振仪应用于各个行业解决了复杂的技术问题,并提高了激光测振仪作为独特测量工具的权威性。从这个角度来看,核工业是一个有趣且有吸引力的应用领域,其测量系统具有特定且严格的开发条件。这项工作的目的是评估激光多普勒振动法相对于核电站的所有优缺点。 (NPP)设备检查。切尔诺贝利核电站是实现这些目的的理想场所。使用激光多普勒振动计已经证明了对不同切尔诺贝利核电厂的诊断能力(例如,第三动力单元主循环器,第五涡轮发电机的轴承轴和各种管道)。用标准的切尔诺贝利NPP振动测量工具检查了激光振动计的测量结果。激光多普勒振动计(CLV,Polytec GmbH和LDV,基辅大学)已经过测试,并显示出在NPP区域中处于0.5 sievert /小时的辐射水平,高电磁场(磁场分量高达5 kA / m)和剧烈振动的全部功能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号