In this paper, the importance of voltage and reactive power control in substation is clarified, and the voltage and reactive power control of substation based on nine-zone graph is introduced. In view of the shortcomings of traditional 'nine-zone graph' control strategy, This paper analyzes the application of artificial intelligence control technology in voltage and reactive power control, and points out the advantages and disadvantages of various control strategies. Finally, this paper summarizes the current situation and the future development of substation voltage and reactive power control in China.
机译:阐明了变电站电压无功控制的重要性,介绍了基于九区图的变电站电压无功控制。针对传统的“九区图”控制策略的不足,本文分析了人工智能控制技术在电压无功控制中的应用,指出了各种控制策略的优缺点。最后,总结了我国变电站电压无功控制的现状和发展趋势。