首页> 外文会议>Electrotechnical Conference (MELECON), 2012 16th IEEE Mediterranean >Induction motor fault diagnosis using an improved combination of Hilbert and Park transforms
【24h】

Induction motor fault diagnosis using an improved combination of Hilbert and Park transforms

机译:使用Hilbert和Park变换的改进组合进行感应电动机故障诊断

获取原文
获取原文并翻译 | 示例

摘要

In this work we propose an original failure signature based on an improved combination of Hilbert and Park transforms. Starting from this combination we can release two failure signatures: Hilbert modulus current space vector (HMCSV) and Hilbert phase current space vector (HPCSV). These two signatures are subsequently analysed using the classical fast Fourier transform (FFT). The effects of HMCSV and HPCSV spectrums are described and the related frequencies determined. This analysis offers an easy interpretation to conclude on the induction motor condition and its voltage supply state. The proposed signature shows its effectiveness and its robustness in both electrical and mechanical fault detection. This approach was applied to a 1.1 kw induction motor under normal operation and with the following fault: voltage unbalanced, broken rotor bar, air-gap eccentricity and ball bearing defect.
机译:在这项工作中,我们提出了一种基于希尔伯特和帕克变换的改进组合的原始故障签名。从这种组合开始,我们可以释放两个失效特征:希尔伯特模数当前空间向量(HMCSV)和希尔伯特相当前空间向量(HPCSV)。随后使用经典快速傅里叶变换(FFT)分析这两个签名。描述了HMCSV和HPCSV频谱的影响并确定了相关频率。该分析为感应电动机状况及其供电状态的结论提供了简单的解释。提议的签名显示了其在电气和机械故障检测中的有效性和鲁棒性。该方法已应用于1.1 kW感应电动机,该电动机在正常操作下具有以下故障:电压不平衡,转子条损坏,气隙偏心率和滚珠轴承故障。