摘要

There are many different methods of employing a high potential test on a stator winding. Three such methods that this paper will explore with reference to one another are the AC (50-60 Hz), DC, and very low frequency (VLF) (0.1 Hz). Some users choose the AC high potential test knowing that this test best simulates the voltage stress on the winding while in service. Other users prefer the DC high potential test largely due to ease in performing the test. However, the DC voltage does not stress the stator coils the same way as when they are in service and may result in overly pessimistic results due to the influence of surface contaminants in the end windings. Finally, the VLF test, due to recent advances in technology, is becoming more practical for use in field conditions. However, the present standard governing the test is almost 40 years old and there is significant interest in what VLF voltage level best correlates with the AC and DC high potential tests. This paper reports preliminary test results on three generator windings that were destructively tested using the AC, DC, and VLF methods as part of an ongoing effort to provide a database upon which to set the appropriate VLF hipot level for modern synthetic resin-based stator insulation systems.
机译:有许多不同的方法可以对定子绕组进行高电势测试。本文将相互探讨的三种方法是交流(50-60 Hz),直流和极低频(VLF)(0.1 Hz)。一些用户选择了交流高电势测试,因为该测试可以最好地模拟使用中绕组上的电压应力。其他用户更喜欢直流高电势测试,这是因为它易于执行测试。但是,直流电压不会像使用中的定子线圈那样对定子线圈施加压力,并且由于端部绕组中表面污染物的影响,可能导致过于悲观的结果。最后,由于技术的最新发展,VLF测试在现场条件下的使用变得越来越实用。但是,目前用于测试的标准已有40年的历史了,人们对什么是VLF电压水平与AC和DC高电势测试最相关的兴趣很大。本文报告了使用AC,DC和VLF方法进行了破坏性测试的三个发电机绕组的初步测试结果,作为正在进行的工作的一部分,以提供一个数据库来为现代合成树脂基定子绝缘设置合适的VLF耐压等级系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号