Personal computers (PC's) being electronic load draw non-sinusoidal current. When this non-sinusoidal current passes through the impedance of the line/cable, it causes considerable distortion in voltage. This distorted voltage in a parallel connection scheme appears at the LT/HT sides of distribution transformer and causes significant effects on equipment performance which are designed to operate at sinusoidal voltage and current only. In this research paper, the complete distribution network of Rachna College of Engineering & Technology (RCET), Pk has been simulated using electrical transient analyzer program (ETAP) software. For this purpose an experiment has been performed in which current waveform drawn by a PC along with its spectrum has been recorded using oscilloscope at RCET Research Lab as prototype. This model of a single PC is injected into the harmonic library of ETAP for simulation of RCET distribution network. The impacts of harmonics caused by PC's on distribution transformers have been completely analyzed in this research work. Moreover, the trend of total harmonic distortion (THD) with variation in different types of loads has been analyzed mathematically & graphically.
机译:具有电子负载的个人计算机(PC)吸收非正弦电流。当此非正弦电流通过线路/电缆的阻抗时,会引起电压的明显失真。在并联连接方案中,这种失真的电压出现在配电变压器的LT / HT侧,对设备性能产生重大影响,这些设备设计为仅在正弦电压和电流下工作。在本文中,Rkna工程技术学院(RCET)Pk的完整配电网络已使用电瞬态分析仪程序(ETAP)软件进行了仿真。为此,已进行了一项实验,其中使用RCET Research Lab的示波器作为原型记录了PC汲取的电流波形及其频谱。将该单台PC的模型注入到ETAP的谐波库中,以仿真RCET配电网络。在这项研究工作中,已经完全分析了由PC引起的谐波对配电变压器的影响。此外,已经通过数学和图形方式分析了不同类型负载中总谐波失真(THD)的变化趋势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号