【24h】

DESIGN OF HIGH-BAY CLEANROOMS AND AIR FLOW ANALYSIS BY COMPUTATIONAL FLUID DYNAMICS

机译:计算流体动力学的高通量洁净室设计和气流分析

获取原文
获取原文并翻译 | 示例

摘要

A high-bay cleanroom tends to accumulate more particles in air streams than a regular sizerncleanroom and causes higher possibility of contamination to the products. This is due to the fact that airrntravels a longer distance in a high-bay cleanroom than a regular size cleanroom. This paper exploresrnsome design practices on how to reduce the particle accumulation rate in a high-bay cleanroom. As anrnexample, how to reduce the size of the vortex behind a big equipment or product under manufacturing inrnthe cleanroom is discussed. Computational Fluid Dynamics (CFD) is used as a tool in the analysis tornpredict flow properties including velocity, flow rate and pressure.
机译:与常规尺寸的洁净室相比,高隔间的洁净室倾向于在空气流中积聚更多的颗粒,并导致更高的产品污染可能性。这是由于这样的事实,即高架洁净室中的空气行程比常规尺寸的洁净室更长。本文探讨了如何降低高棚洁净室中颗粒堆积率的一些设计实践。作为一个示例,讨论了如何减小在洁净室中制造的大型设备或产品背后的涡流尺寸。计算流体动力学(CFD)被用作分析中的工具,以预测包括速度,流速和压力在内的流动特性。