首页> 外文会议>Conference on radiation detectors in medicine, industry, and national security >X-ray backscatter radiography with lower open fraction coded masks
【24h】

X-ray backscatter radiography with lower open fraction coded masks

机译:X射线反向散射射线照相术,其下开口分数编码的掩模较低

获取原文
获取原文并翻译 | 示例

摘要

Single sided radiographic imaging would find great utility for medical, aerospace and security applications. While coded apertures can be used to form such an image from backscattered X-rays they suffer from near field limitations that introduce noise. Several theoretical studies have indicated that for an extended source the images signal to noise ratio may be optimised by using a low open fraction (<0.5) mask. However, few experimental results have been published for such low open fraction patterns and details of their formulation are often unavailable or are ambiguous. In this paper we address this process for two types of low open fraction mask, the dilute URA and the Singer set array. For the dilute URA the procedure for producing multiple 2D array patterns from given 1D binary sequences (Barker codes) is explained. Their point spread functions are calculated and their imaging properties are critically reviewed. These results are then compared to those from the Singer set and experimental exposures are presented for both type of pattern; their prospects for near field imaging are discussed.
机译:单面射线照相成像将在医学,航空航天和安全应用中找到巨大的用途。尽管编码孔径可用于由反向散射的X射线形成这样的图像,但它们受到引入噪声的近场限制的困扰。多项理论研究表明,对于扩展源,可以通过使用低开放分数(<0.5)蒙版来优化图像信噪比。但是,对于这种低开口率模式,很少有实验结果发表,其配方细节通常不可用或模棱两可。在本文中,我们针对两种类型的低开口率掩模(稀URA和Singer集阵列)解决此过程。对于稀的URA,说明了从给定的1D二进制序列(巴克码)产生多个2D阵列图案的过程。计算它们的点扩散函数并严格审查其成像特性。然后将这些结果与Singer装置的结果进行比较,并给出了两种图案的实验曝光。讨论了其近场成像的前景。

著录项

  • 来源
  • 会议地点 San Diego(US)
  • 作者单位

    Cranfield Forensic Institute, Cranfield University, Defence Academy of the United Kingdom, Shrivenham, SN6 8LA, United Kingdom;

    Cranfield Forensic Institute, Cranfield University, Defence Academy of the United Kingdom, Shrivenham, SN6 8LA, United Kingdom;

    Cranfield Forensic Institute, Cranfield University, Defence Academy of the United Kingdom, Shrivenham, SN6 8LA, United Kingdom;

    Cranfield Forensic Institute, Cranfield University, Defence Academy of the United Kingdom, Shrivenham, SN6 8LA, United Kingdom;

    Counter Terrorism Security Division, Defence Science and Technology Laboratory, Fort Halstead, TN14 7BP, United Kingdom;

    Counter Terrorism Security Division, Defence Science and Technology Laboratory, Fort Halstead, TN14 7BP, United Kingdom;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Coded masks; coded apertures; lower open fraction; 3D printed; X-ray backscatter; dilute URA; singer set;

    机译:编码口罩;编码孔较低的开放分数; 3D打印; X射线反向散射;稀释URA;歌手套装;