Our team at Los Alamos National Laboratory has successfully employed Compton spectrometers to measure the X-ray spectra of both continuous and flash radiographic sources. In this method, a collimated beam of X-rays incident on a converter foil ejects Compton electrons. A collimator may be inserted into the entrance of the spectrometer to narrow the angular acceptance of the forward-scattered electrons, which then enter the magnetic field region of the spectrometer. The position of the electrons at the magnet's focal plane is proportional to the square root of their momentum, allowing the X-ray spectrum to be reconstructed. A new samarium-cobalt spectrometer with an energy range of 50 keV to 4 MeV has been fielded at two facilities. The X-ray generating machines produced intense photon beams (> 4 rad at 1 m) with spectral endpoints below 3 MeV. Recent experimental results will be presented.
机译:我们位于洛斯阿拉莫斯国家实验室的团队已成功使用康普顿光谱仪来测量连续和闪光射线源的X射线光谱。在这种方法中,入射在转换箔上的准直X射线束会喷射出康普顿电子。可将准直仪插入光谱仪的入口,以缩小前向散射电子的角度接受度,这些电子随后进入光谱仪的磁场区域。电子在磁体焦平面上的位置与它们的动量的平方根成比例,从而可以重建X射线光谱。一种新的。钴光谱仪已在两个设施中投入使用,其能量范围为50 keV至4 MeV。 X射线发生机产生了强烈的光子束(在1 m处> 4 rad),其光谱终点低于3 MeV。将提供最新的实验结果。