Corrosion monitoring tests were carried out to examine the applicability of electrochemical techniques into corrosion control at a fossil power plant operated with Oxygenated Treatment (OT). A once-through type subcritical pressure boiler was employed to corrosion monitoring tests, and its electric capacity is 125 MW. An autoclave system was installed at the inlet of the economizer. The temperature and pressure in the autoclave were maintained at 215 °C and 7 MPa in the case of the full load operation. The corrosion rate of carbon steel was measured under the oxygenated water condition and All Volatile Treatment (AVT) condition using a modified galvanic couple electrochemical technique and the polarization resistance method.The galvanic current and the polarization resistance were varied with the daily load fluctuations of the plant and were corresponded with the corrosion rate of carbon steel obtained from weight loss measurements. These electrochemical measurement test results suggest that these techniques are applicable to the corrosion monitoring under these conditions, and that the galvanic couple method has advantages compared with the polarization resistance method in respect to the accurate and the instantaneous corrosion rate measurement.
机译:进行了腐蚀监测测试,以检验电化学技术在采用加氧处理(OT)的化石发电厂的腐蚀控制中的适用性。一次过式亚临界锅炉用于腐蚀监测试验,其电容量为125兆瓦。高压釜系统安装在节能器的入口处。在满负荷操作的情况下,高压釜中的温度和压力保持在215°C和7 MPa。使用改进的电偶电化学技术和耐极化性方法,在充氧水条件和全挥发处理(AVT)条件下测量了碳钢的腐蚀速率。 电电流和极化电阻随工厂的日负荷波动而变化,并与通过失重测量获得的碳钢的腐蚀速率相对应。这些电化学测量测试结果表明,这些技术适用于在这些条件下的腐蚀监测,并且就准确和瞬时腐蚀速率测量而言,电偶法与极化电阻法相比具有优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号