Missile warning systems (MWS) present unique problems for hardware-in-the-loop (HITL) testing compared to other sensors found on modern day military aircraft and ground vehicles. End-to-end testing of a UV MWS like the AN/AAR-47 and other non-imaging MWS require a stimulator capable of large intensity dynamic range, moderate temporal response, and the capability to provide simultaneous optical signatures to all four systems sensors. These requirements dictate a different type of stimulator than is normally used with more conventional UV, visible, and IR imaging systems using imaging sensors and relatively narrow fields of view (FOV) on the order of 10-30 degrees. This paper describes both the requirements for a nonimaging UV MWS and the design used to satisfies the requirements for hardware and software testing of the AN/AAR-47and other non-imaging UV MWS equipment.
机译:与现代军用飞机和地面车辆上发现的其他传感器相比,导弹预警系统(MWS)在硬件在环(HITL)测试中存在独特的问题。像AN / AAR-47和其他非成像MWS这样的UV MWS的端到端测试需要一个刺激器,该刺激器必须具有大的强度动态范围,适度的时间响应以及向所有四个系统传感器同时提供光学信号的能力。与使用成像传感器和10-30度左右的相对窄视场(FOV)的更常规的UV,可见光和IR成像系统通常使用的刺激器相比,这些要求决定了其类型不同。本文介绍了非成像UV MWS的要求以及用于满足AN / AAR-47和其他非成像UV MWS设备的硬件和软件测试要求的设计。