Detailed studies of mechanisms for producing electrically initiated COIL lasers were previously presented. Results of those studies along with more recent experimental results show that electric excitation is a very complex process that must be investigated with advanced diagnostics. Theoretical studies indicate that fractions of O_2(~1Δ) may be produced in the discharge that will permit lasing of an ElectriCOIL system. Recent kinetic studies indicate a range of useful operating parameters for ElectriCOIL that are analogous to those achieved in the all-chemical device. This can be accomplished at E/N's in the range of 10~(-16) Volt-cm~2 . An experimental test bed has been built up to allow detailed diagnostic measurements of the discharge efficiencies and other experimental parameters. Results of early experiments are presented.
机译:先前已经介绍了产生电激发COIL激光器的机理的详细研究。这些研究的结果以及最近的实验结果表明,电激励是一个非常复杂的过程,必须通过高级诊断程序进行研究。理论研究表明,可能会在放电中产生O_2(〜1Δ)的分数,这会激射ElectriCOIL系统。最近的动力学研究表明,ElectriCOIL的一系列有用操作参数类似于全化学装置中实现的那些。这可以在E / N为10〜(-16)Volt-cm〜2的范围内完成。已经建立了一个实验测试台,可以对放电效率和其他实验参数进行详细的诊断测量。给出了早期实验的结果。