Using a doubled Nd: YAG laser as a spontaneous vibrational Raman scattering source, and a single intensified CCD array at the exit of an imaging monochromator, the Raman scattering system is used to directly measure the concentrations of the O_2 (a~1Δ) and the O_2 (X~3∑) in the chemical oxygen-iodine laser singlet oxygen generator in real time. We present the results from the tests that conducted on a 0.1-mol singlet oxygen-iodine generator. With the current reported uncertainty of the Raman cross-section, the error in the yield measurement is calculated to be less than 8%.
机译:使用一倍的Nd:YAG激光作为自发振动的拉曼散射源,并在成像单色仪的出口处使用一个增强的CCD阵列,该拉曼散射系统用于直接测量O_2(a〜1Δ)和O_2的浓度。实时产生化学氧碘激光单重态氧气发生器中的O_2(X〜3∑)。我们介绍了在0.1摩尔单重态氧碘发生器上进行的测试结果。利用当前报道的拉曼横截面的不确定性,可以计算出屈服测量中的误差小于8%。