We previously developed a dynamic 4D anthropomorphic breast phantom, which can be used to optimize contrast-based breast imaging systems, accounting for patient variability and contrast kinetics [1]. In this study we aim to compare the performance of contrast-enhanced mammographic and tomosyn-thesis imaging protocols followed by temporal subtraction and dual-energy subtraction, qualitatively and quantitatively across a couple of patient models. Signal-difference-to-noise ratio (SDNR) is measured for the six paradigms of contrast enhanced, temporally subtracted, and dual-energy subtracted mammo-graphy and tomosynthesis and compared. The results show how the performance is more dependent on the breast model in mammography than in tomosynthesis. Also, it is observed that dual-energy subtraction can be beneficial in mammography, whereas it is not advantageous in tomosynthesis. Lastly, the results suggest that temporal subtraction in general outperforms dual-energy subtraction.
机译:我们先前开发了一种动态4D拟人化的人体模型,该模型可用于优化基于对比的乳房成像系统,并考虑了患者的变异性和对比动力学[1]。在这项研究中,我们旨在比较定性和定量地在两个患者模型中对比增强的X线断层造影和断层合成成像方案与时间相减和双能相减的性能。测量了对比度增强,时间相减和双能相减乳房X线照相和断层合成的六个范式的信号差噪比(SDNR),并进行了比较。结果表明,相比于断层合成,乳腺X线摄影的表现如何更依赖于乳房模型。而且,观察到双能量减法在乳房X线照相术中可能是有益的,而在断层合成中是不利的。最后,结果表明,时间相减一般优于双能量相减。

著录项

  • 来源
    《Breast imaging》|2012年|658-665|共8页
  • 会议地点 Philadelphia PA(US)
  • 作者单位

    Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, NC,Department of Electrical and Computer Engineering, Duke University, Durham, NC,Department of Radiology, Duke University Medical Center, Durham, NC;

    Department of Radiology, Duke University Medical Center, Durham, NC;

    Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, NC,Department of Electrical and Computer Engineering, Duke University, Durham, NC,Department of Radiology, Duke University Medical Center, Durham, NC,Medical Physics Graduate Program, Duke University, Durham, NC,Department of Biomedical Engineering, Duke University, Durham, NC;

    Department of Electrical and Computer Engineering, Duke University, Durham, NC;

    Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, NC,Department of Electrical and Computer Engineering, Duke University, Durham, NC,Department of Radiology, Duke University Medical Center, Durham, NC,Medical Physics Graduate Program, Duke University, Durham, NC,Department of Biomedical Engineering, Duke University, Durham, NC,Department of Physics. Duke University, Durham, NC;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Virtual Breast Model; Anthropomorphic Breast Model; Tomosynthesis; Mammography; Dual-energy Subtraction; Temporal Subtraction;

    机译:虚拟乳房模型;拟人化的乳房模型;断层合成;乳腺摄影双能减法;时间减法;