摘要

Reliability and validity of measurements is of utmost importance when assessing measuring capability of instruments developed for research. In order to perform an experiment which is legitimate, used instruments must be both reliable and valid. Reliability estimates the degree of precision of measurement, the extent to which a measurement is internally consistent. Validity is the usefulness of an instrument to perform accurate measurements of quantities it was designed to measure. Statistical analysis for reliability and validity control of low-coherence interferometry method for refractive index measurements of biological fluids is presented. The low-coherence interferometer is sensitive to optical path difference between interfering beams. This difference depends on the refractive index of measured material. To assess the validity and reliability of proposed method for blood measurements, the statistical analysis of the method was performed on several substances with known refractive indices. Analysis of low-coherence interferograms considered the mean distances between fringes. Performe'd statistical analysis for validity and reliability consisted of Grubb's test for outliers, Shapiro-Wilk test for normal distribution, T-Student test, standard deviation, coefficient of determination and r-Pearson correlation. Overall the tests proved high statistical significance of measurement method with confidence level < 0.0001 of measurement method.
机译:在评估为研究而开发的仪器的测量能力时,测量的可靠性和有效性至关重要。为了进行合法的实验,使用过的仪器必须既可靠又有效。可靠性估计测量的精确度,即测量在内部一致性的程度。有效性是一种工具,可以对设计要测量的数量进行准确的测量。介绍了低相干干涉法测量生物液体折射率的可靠性和有效性控制的统计分析。低相干干涉仪对干涉光束之间的光程差敏感。该差异取决于被测材料的折射率。为了评估所提出的血液测量方法的有效性和可靠性,对该方法进行了统计分析,并对几种折射率已知的物质进行了分析。低相干干涉图的分析考虑了条纹之间的平均距离。对有效性和可靠性进行的统计分析包括离群值的Grubb检验,正态分布的Shapiro-Wilk检验,T-Student检验,标准偏差,测定系数和r-Pearson相关性。总体而言,测试证明该方法具有较高的统计显着性,其置信度<0.0001。

著录项

  • 来源
    《Biophotonics-Riga 2013》|2013年|90320Q.1-90320Q.9|共9页
  • 会议地点 Riga(LV)
  • 作者单位

    Department of Metrology and Optoelectronics, Gdansk University of Technology G. Narutowicza 11/12, 80-233 Gdansk, Poland;

    Department of Metrology and Optoelectronics, Gdansk University of Technology G. Narutowicza 11/12, 80-233 Gdansk, Poland;

    Laboratory of Medicinal Chemistry and Neuroengineering, Medical University of Lublin W. Chodzki 4a Street, 20-093 Lublin, Poland;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    validity; reliability; low-coherence interferometer;

    机译:有效性可靠性;低相干干涉仪;
  • 入库时间 2022-08-26 13:58:22

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号