Laser tissue welding predosimetry studies are performed on Wistar rat skin by using diode-pumped and fiber-coupled Thulium (Tm:YAP) laser system emitting at 1980 nm, which is developed for medical applications. The success of laser tissue welding at 100 mW ve 160 mW of Tm:YAP laser powers is analyzed by macroscopy and histology results. Tm:YAP laser dosimetry of 100 mW, 5 second (34,66 W/cm2) is found successful for tissue welding studies.
机译:通过使用二极管泵浦和光纤耦合的((Tm:YAP)发射1980纳米的激光系统对Wistar大鼠皮肤进行激光组织焊接剂量学研究,该系统是为医疗应用而开发的。通过宏观和组织学结果分析了在100 mW到160 mW的Tm:YAP激光功率下激光组织焊接的成功。发现100mW,5秒(34,66 W / cm 2 )的Tm:YAP激光剂量法成功用于组织焊接研究。