【24h】

POLARISATION EFFECT ON CONCRETE CATHODIC PROTECTION CRITERIA

机译:极化对混凝土阴极保护标准的影响

获取原文
获取原文并翻译 | 示例

摘要

Although cathodic protection (CP) to the above ground reinforced concrete structures was first applied around 30 years ago, the CP criteria for such application are still being researched. Among all the currently used CP criteria, the 100 mV potential decay criterion is considered to be the most pragmatic and generally achievable. There are some laboratory studies that suggest to formulate a "current density" criterion as a step forward. The current density requirement, however, decreases with time, to maintain the same level of polarization/depolarization such as 100mV decay. The relationship between the current density and polarization level & period is discussed in this paper. Laboratory study results and the relevant data from an actual installation are presented. It is shown that the current density requirement to achieve a particular level of polarization decreases with time as expected.
机译:尽管大约30年前首次对地上钢筋混凝土结构进行了阴极保护(CP),但仍在研究用于这种应用的CP标准。在所有当前使用的CP准则中,100 mV电位衰减准则被认为是最务实且通常可以实现的准则。有一些实验室研究建议制定“电流密度”标准,以作为向前的一步。但是,电流密度要求会随时间降低,以保持相同的极化/去极化水平,例如100mV衰减。本文讨论了电流密度与极化水平和周期之间的关系。介绍了实验室研究结果和实际安装中的相关数据。结果表明,达到特定极化水平的电流密度要求如预期的那样随时间降低。

著录项