Serious damage to copper tubing brought about by the phenomenon of "ant nest corrosion" (ANC) continues to occur in the heating, ventilation and air conditioning (HVAC) industry. One specific example, reported in a paper to this Conference in 2000, was found on chilled water copper tube protected by thermal insulation in a large air conditioned building. Work since then has identified that the problem appears to occur when defects in the insulation vapour barrier exist. This leads to moisture ingress and subsequent reaction at the copper surface with a sealant material that is widely used by the building industry for the purpose described above. In this paper, we report on free fatty acids in the sealant that were found to react with copper, the most predominant one being 2 ethyl hexanoic acid. Though not formally established, these acids (or their triglycerides) appear to breakdown in the presence of water to yield formic and acetic acids, the two acids implicated in ANC on copper. We also report on methods to combat this effect, firstly by incorporating small amounts of magnesium oxide to neutralize the original acids and secondly by using more inert sealants such as those of a petrolatum base.
机译:在采暖,通风和空调(HVAC)行业中,“蚁巢腐蚀”(ANC)现象对铜管造成的严重破坏仍在继续。在2000年向本次大会提交的一篇论文中报道了一个具体示例,该示例是在大型空调建筑中,用保温材料保护的冷水铜管。从那以后的工作已经确定,当绝缘蒸汽屏障中存在缺陷时,似乎会出现问题。这导致水分进入并随后在铜表面与密封剂材料发生反应,该密封剂材料被建筑行业广泛用于上述目的。在本文中,我们报告了密封剂中与铜发生反应的游离脂肪酸,其中最主要的是2-乙基己酸。尽管尚未正式确定,但这些酸(或其甘油三酸酯)在水存在下会分解,生成甲酸和乙酸,这两种酸与ANC牵连在铜上。我们还报告了解决此问题的方法,首先通过掺入少量氧化镁以中和原始酸,其次通过使用更多的惰性密封剂(例如凡士林碱)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号