This paper presents the design and construction of measuring systems for recording lightning surge voltage in a 230 kV overhead lines. The measuring systems consist of high voltage divider and low voltage impulse recorder. The high voltage divider was designed as a damped capacitor voltage divider having the voltage ratio of 1318. The constructed divider was tested for BIL and AC withstand in accordance with IEC No. 71. The surge voltage on the low voltage side of the voltage divider was measured and recorded by means of remote surge detector and surge recorder, which was designed by using Field Programmable Gate Rays (FPGA) and computer technology. The characteristics of the measuring system was tested in accordance with IEC No. 60-2. The reliability of the measuring system was checked in the high voltage laboratory by applying the lightning impulse voltage superimposed on AC 50 Hz voltage. The designed and constructed measuring system has been installed in the 230 kV substation for 15 months. The waveform and amplitude of lightning surge voltage were recorded. The measured results are illustrated and discussed.
机译:本文介绍了用于记录230 kV架空线路中雷电浪涌电压的测量系统的设计和构造。测量系统由高压分压器和低压脉冲记录仪组成。高压分压器被设计为具有1318的电压比的阻尼电容器分压器。已构建的分压器根据IEC No. 71进行了BIL和AC耐压测试。分压器低压侧的浪涌电压为通过使用现场可编程门射线(FPGA)和计算机技术设计的远程电涌检测器和电涌记录器测量和记录数据。测量系统的特性已根据IEC 60-2进行了测试。通过在交流50 Hz电压上叠加雷电冲击电压,在高压实验室中检查了测量系统的可靠性。设计建造的测量系统已在230 kV变电站中安装了15个月。记录雷电浪涌电压的波形和幅度。测量结果进行了说明和讨论。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号