The paper is concerned with the effect of CT Y- delta transform on measure of sympathetic inrush in order to discuss whether the existing inrush current identification algorithms are applicable to sympathetic inrush. According to the characteristics of sympathetic inrush, the effect of CT Y-delta transform on second harmonic proportion of differential current is investigated in the case of the direction of two phases sympathetic inrush deviated from time axis is same or not. Theory analysis and simulation show that second harmonic proportion of differential current may be less than that of each phase inrush current while direction of two phase sympathetic inrush is reverse. Thus, second harmonic proportion may decrease due to CT Y-delta transform, and transformer differential relays may mal-operate in this condition. It is believed that the study will provide a theoretical basis to discover the inherent reason for mal-operation of transformer differential relays caused by sympathetic inrush.
机译:为了探讨现有的涌流识别算法是否适用于交感涌流,研究了CTY-Δ变换对交感涌流的影响。根据交感突波的特性,研究了在两相交感涌的方向与时间轴偏离相同或不同的情况下,CTY-δ变换对差动电流二次谐波比例的影响。理论分析和仿真结果表明,当两相同相涌流的方向相反时,差动电流的二次谐波比例可能小于各相涌流的谐波分量。因此,由于CT Y-delta变换,二次谐波比例可能会降低,并且变压器差动继电器在这种情况下可能会出现故障。可以认为,该研究将为发现由同感涌流引起的变压器差动继电器误动作的内在原因提供理论依据。