This paper has made an exergy analysis of the performance of a 600 MW thermal power plant at specific load of 470 MW, and studied on the exergy loss and its distributing of each subsystem and equipment. The results show that the exergy loss of the whole system is about 1111.41MJ, and the exergy efficiency of the whole system is 30.75% or so. Additionally, we also found that the exergy loss of the boiler combustion system and heat transfer process is the most part. The results can let us understand the essence of the energy loss better, and provide the guidance for energy saving of the power plant.
机译:本文对一个600 MW火力发电厂在470 MW特定负载下的性能进行了火用分析,并研究了每个子系统和设备的火用损失及其分布。结果表明,整个系统的火用损耗约为1111.41MJ,整个系统的火用效率约为30.75%。此外,我们还发现,锅炉燃烧系统的火用损失和传热过程是最主要的。结果可以使我们更好地了解能源损失的本质,为电厂节能提供指导。