Analytical Method for Performance Degradation of Voltage Limiting Type SPD Based on Leakage Current Measurement

机译:基于漏电流测量的限压型SPD性能下降的解析方法

获取原文

摘要

SPD degradation analysis is a key technology of intelligent SPDs. MOV varistor is the core component of voltage limiting type SPD. It is well known that the increase of leakage current is the main factor causing MOV degradation. Therefore, the monitoring of MOV leakage current is the key to judge the operating condition of voltage limiting type SPD. According to the monitored object, it is divided into two categories: the method of full current and the method of resistive current. The full current is simple to implement, since the response sensitivity is low in the initial stage of SPD degradation, which is more common in some low-cost applications; the resistive current measurement method is more complicated to carry out, but can reflect the degradation trend of SPD sensitively and accurately, which is usually applied in some high demand schemes. The measurement methods of resistive current mainly include: active loss, compensation, phase, and harmonic analysis. This paper introduces several methods of leakage current testing, and analyzes the characteristics of various methods. Through a series of experimental data, the measured leakage current data is used to analyze the degradation trend of SPD.
机译:SPD降级分析是智能SPD的一项关键技术。 MOV压敏电阻是限压型SPD的核心组件。众所周知,泄漏电流的增加是引起MOV下降的主要因素。因此,监控MOV泄漏电流是判断限压型SPD工作状态的关键。根据被监视对象,可分为两类:全电流方法和电阻电流方法。全电流易于实现,因为在SPD降级的初始阶段响应灵敏度较低,这在某些低成本应用中更为常见。电阻电流测量方法执行起来较为复杂,但可以灵敏而准确地反映SPD的退化趋势,通常用于一些高要求方案中。电阻电流的测量方法主要包括:有功损耗,补偿,相位和谐波分析。本文介绍了几种泄漏电流测试方法,并分析了各种方法的特点。通过一系列实验数据,测得的泄漏电流数据可用于分析SPD的退化趋势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号