The Power Line Carrier (PLC) system used in HVDC converter station is connected directly to the primary system via coupling devices, and may be interfered by the electromagnetic noise produced by valves or switch operation procedure. In this paper, the EM noise in PLC system of ±500-kV HVDC Converter Station is measured in the steady state. The transient disturbance during the switch operation procedure appearing in PLC system is also taken into account in this paper. The characteristics of EMI in PLC system are analyzed based on the experimental results.
机译:HVDC换流站中使用的电力线载波(PLC)系统通过耦合设备直接连接到主系统,并且可能会受到阀门或开关操作程序产生的电磁噪声的干扰。本文对±500 kV HVDC换流站的PLC系统的稳态噪声进行了测量。本文还考虑了PLC系统中出现的开关操作过程中的瞬态干扰。根据实验结果分析了PLC系统的EMI特性。