A technique to predict the failure rate of a distribution recloser is described in this paper. The prediction is based on field inspection, recloser age, duty cycle, past maintenance, and environment. Because inspection practices differ among utilities, the technique will apply to whatever data is available, and make the best prediction from that data. Examples of using the technique are provided. Predicted failure rates can then be used in system simulations to predict system failure rates and reliability indices.
机译:本文介绍了一种预测配电箱重合器故障率的技术。该预测基于现场检查,重合器寿命,工作周期,过去的维护和环境。由于公用事业之间的检查实践不同,因此该技术将适用于所有可用数据,并根据该数据做出最佳预测。提供了使用该技术的示例。然后可以在系统仿真中使用预测的故障率来预测系统故障率和可靠性指标。