THE ADVANTAGES OF USING MULTIPLE FREQUENCIES FOR EDDY CURRENT EXAMINATION OF CONDENSER TUBING

机译:使用多个频率进行冷凝器管涡流检测的优势

获取原文
获取原文并翻译 | 示例

摘要

An essential element in the eddy current testing methodology is the use of multiple testing frequencies. A true volumetric inspection requires complete penetration of the tube wall from various perspectives. Since prime frequency is set to approximately thirty seven percent standard depth of penetration of the tube wall, additional frequencies are required to gain an accurate and detailed perspective of the defect. In fact, the need for additional frequencies is absolutely necessary to characterize particular defects such as under-deposit corrosion and microbiologically influenced corrosion. In such cases a minimum of three frequencies are required to perform optimum testing. The frequencies will vary from low, midrange to high depending on the material under test. A fourth frequency can also be used to identify tube supports and tubesheets.rnThis paper demonstrates the effects and advantages of utilizing multiple frequencies in the testing process. The result of which is to provide the analyst with sufficient information to call the defects with greater accuracy and reliability. Utilizing a multi-frequency test instrument and standard probes commonly used for testing condenser tubes, tube samples with various defects will be examined utilizing one, two, three and four frequencies. Defect acquisition rates will also be varied and the results reported. The information is useful for determining the number of frequencies required for an effective eddy current test.
机译:涡流测试方法中的一个基本要素是使用多个测试频率。真正的体积检查需要从各个角度完全穿透管壁。由于主要频率设置为管壁穿透的标准深度的百分之三十七左右,因此需要其他频率才能获得准确而详细的缺陷透视图。实际上,绝对需要额外的频率来表征特定缺陷,例如沉积不足的腐蚀和微生物影响的腐蚀。在这种情况下,至少需要三个频率才能执行最佳测试。频率从低,中到高不等,具体取决于被测材料。也可以使用第四个频率来识别管支架和管板。本文演示了在测试过程中利用多个频率的效果和优势。其结果是为分析人员提供足够的信息,以更高的准确性和可靠性来调用缺陷。使用多频测试仪器和通常用于测试冷凝器管的标准探头,将利用一,二,三和四个频率检查具有各种缺陷的管样本。缺陷获取率也将有所不同,并报告结果。该信息对于确定有效涡流测试所需的频率数很有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号