High temperature superheater and reheater headers have been a necessary focus of any boiler life extension project done by the electric utilities. These headers operate at high temperatures in excess of 900 deg F and are subject to thermal stresses and pressure stresses that can lead to cracking and failure. Babcock & Wilcox Company's investigation of these problems began in 1982 focusing on P11 materials (1~1/4Cr-~1/2Mo). Early assessment was limited to dimensional analysis methods which were aimed at quantifying swell due to creep. Condition assessment and remaining useful life analysis methods have evolved since these initial studies. Experience coupled with improved inspection methods and analytical techniques has advanced the life assessment of these hgih temperature headers. In the discussion that follows we will porovide an overview of B&W's approach to header life assessment including the location and causes for header failures. Inspection techniques and analysis methods which are all directed at determining the remaining useful life of these high temperature headers.
机译:高温过热器和再热器联管箱一直是电力公司进行的任何延长锅炉寿命的项目的必要重点。这些集管在超过900华氏度的高温下运行,并承受可能导致破裂和故障的热应力和压力应力。 Babcock&Wilcox公司于1982年开始研究这些问题,重点是P11材料(1〜1 / 4Cr-〜1 / 2Mo)。早期评估仅限于尺寸分析方法,该方法旨在量化蠕变引起的膨胀。自从这些初始研究以来,状态评估和剩余使用寿命分析方法已经得到发展。经验与改进的检查方法和分析技术相结合,已经提高了这些高温温度割台的寿命评估。在随后的讨论中,我们将概述B&W割台寿命的评估方法,包括割台故障的位置和原因。检查技术和分析方法都旨在确定这些高温集管的剩余使用寿命。