首页> 外文会议>Advances in heat transfer and energy conservation >Characteristics of Frosting according to Refrigerant Flow Direction and Tube Arrangement on Heat Exchanger
【24h】

Characteristics of Frosting according to Refrigerant Flow Direction and Tube Arrangement on Heat Exchanger

机译:换热器上根据制冷剂流向和管道布置结霜的特性

获取原文
获取原文并翻译 | 示例

摘要

In order to investigate characteristics of frost formation according to refrigerant flow types and tube arrangements on plate fin-tube heat exchanger, both inline and staggered tube arrangement heat exchangers were operated under cross counter flow and cross parallel flow conditions. As a result of frost experiments, the cross counter flow heat exchanger showed more uniform frost formation than the cross parallel flow heat exchanger in each rows. In early of the frost experiment, the cross counter flow heat exchanger which had staggered tube arrangement showed more active heat transfer than the cross parallel flow heat exchanger. After middle of the experiments, differences of heat transfer rate between the heat exchangers were decreased. However, overall heat transfer rate during the experiments was greatest in staggered tube arrangement under counter flow condition.
机译:为了根据制冷剂流动类型和板翅片管式换热器上的管子布置研究结霜的特性,直管式和交错式管子布置的换热器都在交叉逆流和交叉平行流条件下运行。结霜实验的结果是,横流热交换器比每排交叉流热交换器更均匀地形成霜。在霜冻试验的早期,交错布置的交叉逆流换热器比平行逆流换热器显示出更多的主动传热。经过实验中间,热交换器之间的传热速率差异减小了。然而,在逆流条件下,在交错管布置中,实验期间的总传热速率最大。