We present results obtained from 3D imaging focal plane arrays (FPAs) employing planar-geometry InGaAsP/InP Geiger-mode avalanche photodiodes (GmAPDs) with high-efficiency single photon sensitivity at 1.06 μm. We report results obtained for new 32 x 128 format FPAs with 50 μm pitch and compare these results to those obtained for 32 x 32 format FPAs with 100 μm pitch. We show excellent pixel-level yield-including 100% pixel operability-for both formats. The dark count rate (DCR) and photon detection efficiency (PDE) performance is found to be similar for both types of arrays, including the fundamental DCR vs. PDE tradeoff. The optical crosstalk due to photon emission induced by pixel-level avalanche detection events is found to be qualitatively similar for both formats, with some crosstalk metrics for the 32 x 128 format found to be moderately elevated relative to the 32 x 32 FPA results. Timing jitter measurements are also reported for the 32 x 128 FPAs.
机译:我们目前从3D成像焦平面阵列(FPA)使用平面几何InGaAsP / InP盖革模式雪崩光电二极管(GmAPDs)以及1.06μm的高效单光子灵敏度获得的结果。我们报告了以50μm间距的新32 x 128格式FPA获得的结果,并将这些结果与以100μm间距的32 x 32格式FPA获得的结果进行比较。对于这两种格式,我们都显示出出色的像素级成品率,包括100%的像素可操作性。发现两种类型的阵列的暗计数率(DCR)和光子检测效率(PDE)性能相似,包括基本DCR与PDE的权衡。发现由于像素级雪崩检测事件引起的光子发射而引起的光学串扰在质量上与两种格式相似,并且32×128格式的某些串扰指标相对于32×32 FPA结果有所提高。还报告了32 x 128 FPA的时序抖动测量结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号