This paper describes practical tuning methods and testing of a digital PSS, which uses both frequency and power, with the 220MVA Chungpyung P/P #1 in the KEPCO system to enhance the damping of local modes. In the first step, the objective phase of PSS is computed through a phase leading function to provide compensation between the exciter reference point and the generator air-gap torque before tuning the PSS's time constants. In addition, eigenvalue analysis was used to determine a range of PSS's gain, which is the more useful for field testing rather than a single gain value. The Real-Time Digital Simulator was used to verify safe operations of the PSS in the presence of disturbances, such as A VR step and three phase fault.
机译:本文介绍了使用频率和功率的数字PSS的实用调谐方法和测试,以及KEPCO系统中的220MVA Chungpyung P / P#1,以增强局部模式的阻尼。第一步,通过相位超前函数计算PSS的目标相位,以在调整PSS的时间常数之前在激励器参考点和发电机气隙扭矩之间提供补偿。另外,特征值分析用于确定PSS增益的范围,这对于现场测试比单个增益值更有用。实时数字仿真器用于在存在干扰(例如A VR阶跃和三相故障)的情况下验证PSS的安全操作。