In the heating system,the water ejector can use the "surplus pressure" to pump return water from return pipe instead of using mixing pumps,thus achieving the purpose of energy conservation.The water ejector is normally devised in the design condition,however,it usually does not operate at the design point because the pressure and flow rate of water in water ejector varies with the fluctuation of adjacent heat consumer,which causes the deviation of the indoor air temperature from the designed value.In the present study,the allowed pressure fluctuation of water ejector was investigated under the condition that the indoor air temperature was maintained in a certain range.The experimental results showed that when indoor air temperature was set at 18(+2,-1) oC,the allowed pressure fluctuation range for the water ejector in Harbin was -10%~20%,and it expanded as the outdoor design temperature increased and/or the supply water temperature of primary network reduced.
机译:在加热系统中,喷水器可以利用“过剩压力”从回水管中抽出回水,而不是使用混合泵,从而达到节能的目的。喷水器通常是在设计条件下设计的。通常不会在设计点运行,因为喷水器中的水的压力和流量会随着相邻热消耗的波动而变化,从而导致室内空气温度偏离设计值。在本研究中,允许压力在室内空气温度保持在一定范围内的条件下,研究了喷水器的波动情况。实验结果表明,当室内空气温度设定在18(+ 2,-1)oC时,允许的压力波动范围为25°C。哈尔滨市的喷水量为-10%〜20%,随着室外设计温度的升高和/或一次网供水温度的降低而扩大。