【24h】

Study on Energy Use Characteristics of Hotel Buildings in Shanghai

机译:上海市酒店建筑能耗特征研究

获取原文
获取原文并翻译 | 示例

摘要

This paper presents statistical energy use characteristics of hotel buildings in Shanghai.Building information and energy consumption data had been collected by field survey of 45 star hotels.The hotels were mostly built after 1990s with guest rooms,taking up more than half of the gross floor area.The breakdown of energy use shows that electricity is the main energy source,which accounts for 75% of total energy consumption.The annual average energy use intensity (EUI) for 3-star,4-star and 5-star hotels are 61.95 kgce/m2,73.18 kgce/m2 and 86.64 kgce/m2 respectively by converting all consumed energy into equivalent coal.In addition,some other factors which also affect the energy use in hotel buildings,such as hotel occupancy and hotel's class have been reviewed.This study helps to understand the current energy performance of hotel buildings for further energy retrofit.
机译:本文介绍了上海酒店建筑的统计能耗特征,通过对45家星级酒店的实地调查收集了建筑信息和能耗数据。这些酒店大多是1990年代以后建造的,带有客房,占总楼面的一半以上能源使用细分显示,电力是主要能源,占总能源消耗的75%。三星级,四星级和五星级酒店的年平均能源使用强度(EUI)为61.95。 kgce / m2、73.18 kgce / m2和86.64 kgce / m2分别通过将所有消耗的能源转换为当量煤来进行。此外,还对影响酒店建筑能耗的其他一些因素进行了审查,例如酒店入住率和酒店等级。这项研究有助于了解酒店建筑物当前的能源性能,以进行进一步的能源改造。