To investigate the effect of fire location on smoke temperature distributions in tunnel fires with natural ventilation,the 3-D numerical simulation model were developed using CFD code FDS.The previous works of 1/15 reduced-scale experiments were used to verify the simulation model.Then the effect of train location in tunnel,fire source location in fire carriage and fire carriage in train on tunnel ceiling temperatures were researched.The simulated results indicated that the train location in tunnel didn't have significant effect on ceiling smoke temperatures when all of windows or doors are in the tunnel section containing fire source,but the ceiling smoke temperatures decreased when some windows or doors are beyond the boundary of tunnel section containing fire source.Moreover,the fire source location in fire carriage and the fire carriage in train didn't have significant effect on ceiling smoke temperatures in the tunnel.
机译:为了研究火灾位置对自然通风隧道火灾中烟气温度分布的影响,使用CFD代码FDS建立了3-D数值模拟模型,并使用先前的1/15缩减规模实验进行了验证。然后研究了隧道中的列车位置,消防车中的火源位置和列车中的消防车对隧道顶棚温度的影响。模拟结果表明,在所有情况下,隧道中的列车位置对顶棚烟气温度没有显着影响。的门窗位于装有火源的隧道部分,但当某些门窗超出含有火源的隧道部分的边界时,天花板烟气温度降低。此外,消防车中的火源位置和火车中的消防车对隧道内的天花板烟气温度没有明显影响。