【24h】

Non-symmetrical Plumes Generated by a Single High-rise Building

机译:单个高层建筑产生的非对称羽

获取原文
获取原文并翻译 | 示例

摘要

To study the influence of buoyancy flows generated by a single building on the urban ventila-tion and thermal comfort, an in-situ measurement was carried out on a 50 meter high-rise building. The temperature of wall outside surfaces were measured by infrared camera and thermal couples. The flow along the south facing wall was measured by ultra-sonic anemome-ters. The measurement was taken continuously for 53 hours under clear and calm background weather condition. The building was still under construction when the experiment was con-ducted, so the influence of anthropogenic heat could be minimalized.rnThe Rayleigh number reached 10~(14). The wall surface temperature on different directions are different. Therefore, the magnitude of the flow speed generated by natural convection along different walls are different. The flows generated by different walls above the building roof will merge into one thermal plume. The non-symmetrical plume will be formed above the building roof. (148 words)
机译:为了研究单个建筑物产生的浮力流对城市通风和热舒适性的影响,对一幢50米高的高层建筑进行了现场测量。壁外表面的温度通过红外热像仪和热电偶测量。沿南向壁的流量由超声波风速仪测量。在晴朗和平静的背景天气条件下连续53小时进行测量。进行实验后,建筑物仍在建造中,因此可以将人为热量的影响降到最低。瑞利数达到10〜(14)。不同方向的壁面温度不同。因此,自然对流沿不同壁产生的流速大小不同。建筑物屋顶上方不同墙壁产生的气流将合并为一根热羽。非对称羽流将形成在建筑物屋顶上方。 (148个字)