With energy shortage issue rises, value of energy conservation grows. The energy consumption of HVAC system reaches about 50% of the building especially for the hot and humid ambient condition in Taiwan. Energy modelling code eQUEST was applied to evaluate the energy consumption of a hotel building. Through the validation of simulation data and field measurement data, the energy-efficient chiller sizing approach can be obtained. The results revealed that the energy saving of 10.5% can be achieved by optimizing the chiller capacity sizing. The approach by energy modelling in this study will identify the best practice under limited budget as well as to reduce the trial-and-error effort while chiller sizing decision for energy saving have to be carried out.
机译:随着能源短缺问题的增加,节能的价值也随之增长。暖通空调系统的能耗约占建筑物的50%,尤其是在台湾炎热潮湿的环境下。能源建模代码eQUEST被用于评估酒店建筑物的能耗。通过对仿真数据和现场测量数据的验证,可以获得节能型冷水机组的选型方法。结果表明,通过优化冷却器容量选型可以实现10.5%的节能。本研究中采用能源建模的方法将确定有限预算下的最佳实践,并减少反复试验的工作量,同时必须进行节能的冷水机组规模决策。