Indoor air quality has attracted more and more attention nowadays.Researches on the atmospheric haze occurred frequently in China show that the ventilated window has a great potential in improving indoor air quality.Experimental study on the effect of indoor air quality,indoor thermal environment and whole energy consumption of the test room,which are all tested under summer conditions.The results show that operating the ventilated window can filter PM2.5 and reduce the indoor concentration of CO2; While outdoor and indoor air PM2.5 concentration are about 0.1-0.3mg/m3 and 0.04-0.13mg/m3,respectively,indoor air PM2.5 concentration will decrease 25% at most in an hour,it is suitable for running ventilated window; While outdoor air PM2.5 concentration is 0.3-0.6mg/m3 and indoor air PM2.5 concentration is less than 0.13mg/m3,the indoor air PM2.5 concentration will increase 90%~128%,so the ventilation window should be shut down; Operating the ventilated window one hour indoor CO2 concentration is reduced 46% at most,compared with that the ventilated window is shut down; When the indoor and outdoor air temperature difference is 12-14°C,operating the ventilated window has little influence on head-foot temperature difference and indoor thermal comfort; When a ventilated window runs 24 hours continuously,its power consumption itself is very low,and the overall consumption is smaller compared with the ventilated window is closed,and the energy consumption increases by 10% or so.Therefore the appropriate operation methods and time of ventilated windows need to be set to reduce energy consumption.
机译:如今,室内空气质量越来越受到人们的关注。对中国大气雾霾的频繁研究表明,通风窗具有改善室内空气质量的巨大潜力。室内空气质量,室内热环境以及整体空气质量的影响的实验研究结果表明,操作通风窗可以过滤PM2.5并降低室内的CO2浓度。当室内外空气中PM2.5浓度分别为0.1-0.3mg / m3和0.04-0.13mg / m3时,室内空气中PM2.5浓度最多在一小时内降低25%,适用于运行通风窗;当室外空气PM2.5浓度为0.3-0.6mg / m3,室内空气PM2.5浓度小于0.13mg / m3时,室内空气PM2.5浓度将增加90%〜128%,因此通风窗应关掉;使用通风窗,与关闭通风窗相比,一小时室内二氧化碳浓度最多降低46%。当室内和室外空气温度差为12-14°C时,操作通风窗对头脚温度差和室内热舒适性影响不大;当通风窗连续运行24小时时,其能耗本身​​很低,与关闭通风窗相比,其总能耗较小,能耗增加了10%左右。因此,适当的操作方法和时间需要设置通风窗以减少能耗。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号