A recent comprehensive review of underfloor air distribution (UAD) systems literature and interviews with engineers (who have a significant number of completed projects using these systems) has shown that the use of UAD system results in measurable improvements in thermal comfort, indoor air quality, and user satisfaction. These systems support changing space layouts with continued levels of HVAC delivery, and provide high level of user control. Frequently, the UAD systems show first-cost savings over more conventional ceiling systems, churn-cost savings ranging from $10 - $50 per square meter per move, and savings of 5-35% in energy consumption. Finally, facility management costs are often reduced. In this paper, we discuss the findings from the above-mentioned review in the context of different UAD system approaches, comparing their performance to traditional ceiling-based systems. Specifically, we discuss the reasons for better air quality, reduction in peak and operational energy use, and lower first and life cycle costs of these systems.
机译:最近对地板空气分配(UAD)系统文献进行的全面审查以及对工程师(使用这些系统的大量已完成项目的工程师)的采访显示,使用UAD系统可显着改善热舒适度,室内空气质量,和用户满意度。这些系统通过不断提供HVAC来支持不断变化的空间布局,并提供高水平的用户控制。通常,与更传统的天花板系统相比,UAD系统显示出第一笔成本节省,每移动一次每平方米可节省的成本在10美元至50美元之间,能耗降低5-35%。最后,设施管理成本通常会降低。在本文中,我们将在不同的UAD系统方法的背景下讨论上述评论的结果,并将其性能与传统的基于天花板的系统进行比较。具体来说,我们讨论了改善空气质量,减少峰值能耗和运营能耗以及降低这些系统的首次使用和生命周期成本的原因。