首页> 外文会议>7th international conference on magnetic refrigeration at room temperature >THERMAL LOSS ESTIMATION FOR ACTIVE MAGNETIC REGENERATOR AIMING AT RAILWAY AIR-CONDITIONER APPLICATION
【24h】

THERMAL LOSS ESTIMATION FOR ACTIVE MAGNETIC REGENERATOR AIMING AT RAILWAY AIR-CONDITIONER APPLICATION

机译:针对铁路空调应用的有源磁蓄热器的热损失估算

获取原文
获取原文并翻译 | 示例

摘要

We carried out a basic experiment and numerical analysis for estimating the losses quantitatively. A heat transfer fluid back and forth moving in an active magnetic regenerator (AMR) mixes with the fluid in the plumbing connected to the AMR at both ends of the AMR. Mixing of those fluids that have different temperatures causes a decreasing of the cooling capacity. It was found out that displacers placed at the both ends of the AMR could prevent those fluids from mixing. The result of the numerical analysis that considered the heat leak from the ambient temperature had a good agreement to the result of the experiment of the AMR with displacers placed at the both ends of the AMR.
机译:我们进行了基础实验和数值分析,以定量估算损失。在有源磁蓄热器(AMR)中来回运动的传热流体与在AMR两端连接到AMR的管道中的流体混合。具有不同温度的那些流体的混合导致冷却能力的降低。已经发现,放置在AMR两端的置换器可以防止这些流体混合。考虑到环境温度的热泄漏的数值分析结果与AMR两端都放置有置换器的AMR实验结果非常吻合。

著录项

  • 来源
  • 会议地点 Turin(IT)
  • 作者单位

    Cryogenic Systems, Maglev Systems Technology Division, Railway Technical Research Institute Hikari-cho, Kokubunji-shi, Tokyo, Japan Department of Mechanical Engineering, Kobe University Rokkodai-cho, Nada-ku, Kobe, Japan E-mail: miyazaki.yoshiki.23@rtri.or.jp;

    Cryogenic Systems, Maglev Systems Technology Division, Railway Technical Research Institute Hikari-cho, Kokubunji-shi, Tokyo, Japan epartment of Mechanical Engineering, Kobe University Rokkodai-cho, Nada-ku, Kobe, Japan;

    Cryogenic Systems, Maglev Systems Technology Division, Railway Technical Research Institute Hikari-cho, Kokubunji-shi, Tokyo, Japan;

    Department of Mechanical Engineering, Kobe University Rokkodai-cho, Nada-ku, Kobe, Japan;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Thermal loss; magnetic heat pump; active magnetic regenerator; railway air-conditioner;

    机译:热损失;磁力热泵;有源磁蓄热器;铁路空调;