The use of domestic air conditioner and domestic water heater gradually increased year by year in China.In this paper,a prototype was presented which integrated heat pump air conditioner with heat pump water heater.This system can simultaneously cool down the room and supply domestic hot water in the summer.The unit performance in cooling mode,the heating water mode and cooling/heating water mode were tested respectively and the compressor discharge pressure,the compressor suction pressure,the water temperature、the compressor power,the cooling capacity and the system coefficient of performance in three different modes were analyzed and compared.When the system operated in combined cooling with heating water mode,the system comprehensive COP was higher than that in the separate cooling and separate heating water modes which peak value can reach 7.0.
机译:在中国,家用空调和家用热水器的使用逐年增加。本文提出了一种将热泵空调与热泵热水器集成在一起的样机。该系统可以同时为房间降温并提供家用热水。分别测试了冷却模式,加热水模式和冷却/加热水模式下的机组性能,并测试了压缩机排气压力,压缩机吸气压力,水温,压缩机功率,冷却能力和系统对三种不同模式下的性能系数进行了分析和比较。当系统在采暖与制冷结合的模式下运行时,系统的综合COP高于单独的采暖与分离的采暖模式下的峰值,可以达到7.0。