The chloridizing method using ferrous chloride was employed in this research to thermally treat the EAF dust, some results are as follows: Ferrous chloride can be used to volatilize Zn, Pb, Cd and Cu from EAF dust, the highest recoveries of Zn and Pb reached to 97.50% and 99.47%, respectively. Among the reaction parameters, temperature takes a dominant role in the chloridizing process. Below 1000℃, the increasing of temperature could improve the removal of Zn and Pb from EAF dust. As temperature exceeded 1000℃. there was no obvious increase in the recovery of the desired elements. The best temperature to treat this CDN EAF dust was about 1000℃. The amount of FeCl_2 used has been found some influence on the removal process in this study. For recovery of Zn greater than 95%. more than 55% of FeCl_2 is indicated.
机译:本研究采用氯化亚铁进行氯化处理,对电炉粉尘进行热处理,结果如下:氯化亚铁可以使电炉粉尘中的锌,铅,镉和铜挥发,回收率最高。分别为97.50%和99.47%。在反应参数中,温度在氯化过程中起主要作用。 1000℃以下,温度的升高可以改善电炉除尘中锌和铅的去除。当温度超过1000℃时。所需元素的回收率没有明显增加。处理这种CDN电炉粉尘的最佳温度约为1000℃。在本研究中,已发现FeCl_2的用量对去除过程有一定影响。用于回收锌大于95%。指示超过55%的FeCl_2。