Study on correction approach of complementary double reference potential difference in direct current potential drop method

机译:直流电势下降法中互补双参考电势差的校正方法研究

获取原文
获取原文并翻译 | 示例

摘要

The direct current potential drop(DCPD)method is used to Real-time monitor the crack growing state in environment assisted cracking(EAC)experiments of nuclear structural materials performed in the autoclave designed for simulating high temperature and high pressure water environment.However,the monitoring accuracy and stability should be continuously improved because of the tiny potential difference signal,the zero drift of instrument,specimen temperature resistivity variation and common mode electromagnetic interference etc.
机译:直流电势降(DCPD)方法用于实时监测高压釜中模拟高温高压水环境的核结构材料的环境辅助开裂(EAC)实验中的裂纹生长状态。由于电势差信号小,仪器的零漂移,样品的温度电阻率变化和共模电磁干扰等原因,需要不断提高监测精度和稳定性。