A detailed transient computer analysis of an attic with radiant barriers is presented. The computer model included radiation, forced and free covection, and conduction, as well, as, ventilation in the attic. The solar flux and ambient temperatures were taken to be transient rather than constant. The purpose of the analysis was to determine the impact of varying numerous parameters. The following vriations were studied: ventilation, celiling R values, roof shingle absorptivity/ emissivity, barrier reflectivity, humidity ratio. Of particular interest in the study was the roof sheating temperature increase due to installation of a radiant barrier thuse accelerating deterioration of the roof material. No significant change was detected in the roof sheathing temperature.
机译:介绍了一个带有辐射屏障的阁楼的详细瞬态计算机分析。计算机模型包括辐射,强制对流和自由对流以及传导以及阁楼中的通风。太阳通量和环境温度被认为是瞬时的而不是恒定的。分析的目的是确定变化众多参数的影响。研究了以下变化:通风,精化R值,屋顶瓦吸收率/发射率,屏障反射率,湿度比。在这项研究中,特别令人感兴趣的是由于安装了辐射屏障而导致的屋顶棚温度升高,从而加速了屋顶材料的劣化。屋顶护套温度未检测到明显变化。