首页> 外文会议>4th IET Clean Energy and Technology Conference >Vector controlled AC motor drives for long cable application: Analysis of harmonics at motor terminal
【24h】

Vector controlled AC motor drives for long cable application: Analysis of harmonics at motor terminal

机译:用于长电缆应用的矢量控制交流电动机驱动器:分析电动机端子上的谐波

获取原文
获取原文并翻译 | 示例

摘要

The implementation of long cable connection to AC drives creates harmonic in motor current and voltage, which in turn affects the power quality of the system. This paper presents a detailed analysis of harmonics at motor terminal of vector controlled AC drives for long cable applications. The long cable is represented by 50-m and 100-m cable. Experimental tests are conducted under no-load and load operating conditions with respect to various switching frequency and speed. The real-time implementation of AC drives is done using MATLAB/Simulink program and dSPACE DS1103 controller board. From the analysis, the cable length does not affect the speed response due to high-frequency switching operation of PWM signal. However, it increases the harmonic content in current and voltage of the motor. The THD current and THD voltage increase 5.5% and 12.5% in average respectively when long cable is applied. It is found that the THD voltage is greatly affected by long cable compared to the THD current. These findings provide important insight for future research which is mitigation method of voltage harmonics for the AC drives with long cable connection.
机译:与交流变频器的长电缆连接实现会在电动机电流和电压中产生谐波,进而影响系统的电能质量。本文详细介绍了矢量控制交流变频器在长电缆应用中电机端子处的谐波。长电缆以50米和100米电缆表示。针对各种开关频率和速度,在空载和负载工作条件下进行了实验测试。交流变频器的实时实现是使用MATLAB / Simulink程序和dSPACE DS1103控制器板完成的。根据分析,电缆长度不会由于PWM信号的高频开关操作而影响速度响应。但是,它会增加电动机电流和电压中的谐波含量。使用长电缆时,THD电流和THD电压平均分别增加5.5%和12.5%。已经发现,与THD电流相比,THD电压受长电缆的影响很大。这些发现为将来的研究提供了重要的见识,这是减轻长电缆连接的交流变频器的电压谐波的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号