An Experimental Study of Influences of Contact Opening Speeds on Arcing Behaviors of Silver Contacts

机译:触头打开速度对银触头起弧行为影响的实验研究

获取原文
获取原文并翻译 | 示例

摘要

In order to study the influences of contact opening speeds on break arc behaviors, Ag contacts were operated to break inductive DC load currents from 0.1 A to 2.0 A at 14 V with contact opening speeds of 1 mm/s and 10 mm/s in a switching mechanism employing a stepping motor. Occurrence rates of break arcs and their average durations were determined at each current level under the respective contact opening speeds. From the results, irrespective of the opening speed values, at the conventional minimum arc current level of 0.4A, the arc occurrence rates were almost 100% and the average arc durations were around 20 to 30 μs. This confirmed the author's previous observations in which the conventional minimum arc current level should be considered as the threshold level for arc discharges of certain duration to occur at the rate of almost 100%. The arc occurrence rates below 0.4A were slightly influenced by changes in the contact opening speeds. With respect to arc extinction gaps calculated by multiplying the average arc duration value and the contact opening speed value, it was found that with increasing the contact opening speeds, arc extinction gaps became larger, although they were on the order of several tens μm or less in the tested conditions.
机译:为了研究触头打开速度对断开电弧行为的影响,使用Ag触头在14 V下以1 mm / s和10 mm / s的触头打开速度将感应直流负载电流从0.1 A断开到2.0A。开关机构采用步进电机。断弧的发生率及其平均持续时间是在各个电流水平下以各自的触点打开速度确定的。从结果可知,不管打开速度值如何,在常规最小电弧电流水平为0.4A时,电弧发生率几乎为100%,平均电弧持续时间约为20至30μs。这证实了作者先前的观察,在传统的最小电弧电流水平中,应将常规最小电弧电流水平视为一定持续时间的电弧放电的阈值水平,以近100%的速度发生放电。低于0.4A的电弧发生率受到触点打开速度的变化的轻微影响。对于通过将平均电弧持续时间值和触头打开速度值相乘而计算出的消弧间隙,发现随着消弧速度的增加,消弧间隙变大,尽管其约为几十μm或更小。在测试条件下。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号