ENERGY ANALYSIS OF A WATER-LOOP SELF-CONTAINED SYSTEM VS A MULTIPLEX SUPERMARKET

机译:自给水系统与多层超级市场的​​能量分析

获取原文
获取原文并翻译 | 示例

摘要

Supermarkets are probably the largest energy users in the commercial sector and are responsible for considerable CO_2 emissions. A typical supermarket may consume on the order of million kWh annually. One of the largest uses of energy is for refrigeration, which can be as much as half of the store total. In most cases, refrigeration systems employ direct expansion air refrigerant coils as the evaporators in display cases and coolers. Compressors and condensers are kept in a remote machine room located in the back or on the roof of the store. As a consequence, large amount of refrigerant is needed to charge the refrigeration system, on the order of thousand kg. Furthermore, a significant risk of important annual leakages (on the order of ten percent of the total charge annually) is a consequence of the large number of piping and pipe joints used.rnNowadays advanced supermarket systems can reduce both annual energy consumption and total equivalent warming impact (TEWI). One of these advanced solutions is the water-loop self-contained refrigeration system with modulating compressors (WLSC). In this paper a real WLSC supermarket located in Italy is considered and its performances during the summer period are analyzed and compared with those of a simulated multiplex benchmark solution with fixed evaporation and condensation pressures and thermostatic expansion valve. The comparison shows that the WLSC system leads to a 12.6% electric energy reduction. The main advantage comes from the possibility to decrease the average compression ratio when modulation is required. Moreover the WLSC solution lets a 71% 15-year TEWI reduction, which is mainly possible thanks to drastic reductions of both refrigerant charge and leakages.
机译:超级市场可能是商业领域最大的能源用户,并导致大量的CO_2排放。一个典型的超级市场每年可能消耗数百万千瓦时的电量。能源的最大用途之一是制冷,它可能占到商店总数的一半。在大多数情况下,制冷系统采用直接膨胀的空气制冷剂盘管作为陈列柜和冷却器中的蒸发器。压缩机和冷凝器保存在位于商店后部或屋顶的远程机房中。结果,需要大量的制冷剂来填充制冷系统,大约为千公斤。此外,由于大量管道和接头的使用,每年产生大量重大泄漏(每年约占总费用的百分之十)的巨大风险。如今,先进的超级市场系统可以减少年度能耗和总当量变暖影响(TEWI)。这些先进的解决方案之一是带有调节压缩机(WLSC)的水循环独立式制冷系统。本文考虑了位于意大利的一家真正的WLSC超级市场,并分析了其在夏季的性能,并与具有固定蒸发和冷凝压力以及恒温膨胀阀的模拟多重基准解决方案的性能进行了比较。比较表明,WLSC系统可减少12.6%的电能。主要优点来自于在需要调制时降低平均压缩率的可能性。此外,WLSC解决方案可使15年的TEWI减少71%,这主要是由于制冷剂充注量和泄漏量的大幅减少所致。

著录项

  • 来源
  • 会议地点 London(GB)
  • 作者单位

    Department of Management and Engineering, University of PaduaStr.lla San Nicola 3, Vicenza, 36100, Italy bagarella@gmail.com;

    Department of Management and Engineering, University of Padua Str.lla San Nicola 3, Vicenza, 36100, Italy renato@gest.unipd.it;

    Department of Management and Engineering, University of PaduaStr.lla San Nicola 3, Vicenza, 36100, Italy marco.noro@unipd.it;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号