首页> 外文会议>The 3rd China-Canada joint workshop on supercritical water-cooled reactors >Calculations of thermal junction potential and calibration of an External Pressure-balanced Reference Electrode
【24h】

Calculations of thermal junction potential and calibration of an External Pressure-balanced Reference Electrode

机译:热结电位的计算和外部压力平衡参比电极的校准

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The electrochemical corrosion measurements in subcritical and supercritical aqueous solutionsrequire utilization of reliable reference electrodes. The most widely accepted reference electrode isthe external pressure-balanced reference electrode (EPBRE). This study presents the constructionand characterization of an external pressure-balanced reference electrode to be used in an autoclave.The equilibrium potential measurements were performed using this reference electrode in the Cu/Cu2+ system. The deviation of the measured potential was attributed to i) thermal junction potential, ii)liquid junction potential, and iii) Ohmic voltage drop. The available data were used to estimate themagnitude of these values and compared with the measured values for the Cu/Cu 2+ system.
机译:在亚临界和超临界水溶液中的电化学腐蚀测量需要利用可靠的参比电极。最广泛接受的参比电极是外部压力平衡参比电极(EPBRE)。本研究介绍了高压釜中使用的外部压力平衡参比电极的构造和表征。在Cu / Cu2 +系统中使用该参比电极进行了平衡电位测量。测得电位的偏差归因于i)热结电势,ii)液体结电势和iii)欧姆压降。现有数据用于估计这些值的大小,并与Cu / Cu 2+系统的测量值进行比较。