Recently, MRI (Magnetic Resonance Imaging) examination is an important examinationrnin the medical diagnosis. MRI is a technology to image the distribution of inside of bodyrnwith the nuclear magnetic resonance phenomenon. At this time, noise is generated by usingrnthe gradient magnetic field for decision of the imaging position. The noise level is aroundrn100dB though this noise level depends on the imaging method or the resolution parameter.rnThe noise makes subjects of MRI examination revolted, and it makes the ear-protectorrnnecessary. It is important to know the noise and to measure the noise for soundproofing.rnNow, it is not clear that the driving sound propagates in MRI examination room. We reportrnthe measured result on the sound intensity vector of the driving sound around the gantry ofrnMRI equipment. The probe of the tetra type with four non-magnetic electret condenserrnmicrophones was made for this measurement. Cross-spectral method was adopted forrncalculation of the sound-intensity vector. The analyzed signal was the pulse of the autotuningrnbrought by the first stage of imaging operation. It was shown the sound intensityrnvector of each frequency 250, 500 and 1000Hz in 1/1 octave. And, it was shown the MRIrndriving sound radiated from the gantry side surface.
机译:近年来,MRI(磁共振成像)检查是医学诊断中的重要检查。 MRI是一种利用核磁共振现象对人体内部分布进行成像的技术。此时,通过使用梯度磁场来确定成像位置而产生噪声。尽管此噪声级别取决于成像方法或分辨率参数,但噪声级别仍为约100dB。噪声会使MRI检查的对象产生反感,并且需要护耳器。了解噪声并测量噪声对于隔音很重要。现在,不清楚驾驶声是否在MRI检查室中传播。我们将测量结果报告给MRI设备机架周围驱动声音的声强矢量。制作了带有四个非磁性驻极体电容麦克风的四极探头。采用互谱法对声强矢量进行计算。被分析的信号是成像操作的第一阶段所产生的自整定脉冲。它显示了在1/1八度音阶中每个频率250、500和1000Hz的声强向量。并且,示出了从机架侧表面辐射的MRI驱动声音。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号