After the successful first Round Robin Test (RRT) on microcalorimetry WIWEB; and PB Clermont SA proposed to conduct a follow-up RRT on compatibility, also to be measured by microcalorimetry. The propellant of the first RRT was chosen again for this second RRT. As contact material a lacquer called Gleitmo 980 was selected. It was prepared by WIWEB and sent out to all participants. Thus each laboratory had the same material. The basic measuring principle was fixed by WIWEB and was nearly identical to that of the first RRT. The interlaboratory repeatability was high, the standard deviation of the propellant sample and of the mixture was below 10%. All participants had the possibility to run additional experiments. The measuring temperature, the mixing procedure or the preparation of the contact material was varied in different laboratories. In addition other experiments, like vacuum stability test (VST), weight loss tests or pressure increase experiments were conducted, which increased the understanding of the processes going on in the mixture.
机译:成功进行了首次量热法WIWEB的Round Robin测试(RRT)之后; PB Clermont SA和PB Clermont SA建议对相容性进行后续RRT,也将通过微量量热法进行测量。第一个RRT的推进剂再次被选择用于第二个RRT。作为接触材料,选择了一种名为Gleitmo 980的清漆。它由WIWEB编写,并发送给所有参与者。因此,每个实验室具有相同的材料。基本的测量原理是由WIWEB确定的,几乎与第一个RRT的原理相同。实验室间的重复性很高,推进剂样品和混合物的标准偏差低于10%。所有参与者都有可能进行其他实验。测量温度,混合步骤或接触材料的制备在不同的实验室中有所不同。此外,还进行了其他实验,如真空稳定性测试(VST),失重测试或压力增加实验,这增加了对混合物中进行过程的了解。