Measurement of moisture conditions in cellulose insulated walls and roofs with or without PE-vapour barriers in 32 occupied Danish dwellings

机译:在32个被占领的丹麦住宅中,在有或没有PE蒸汽屏障的情况下,对纤维素绝缘的墙壁和屋顶中的水分条件进行测量

获取原文
获取原文并翻译 | 示例

摘要

In a Danish housing estate moisture sensors have been installed in 32 dwellings part in walls and part in roofs. The walls and roofs were insulated with cellulose insulation and were either with or without PE-vapour barriers. In the paper is described the results from moisture measurements during two winters. Also the indoor climate has been recorded in the dwellings. The result was that under Danish conditions neither the moisture conditions in walls and roofs nor the indoor climate depended on whether a PE-vapour barrier was used or not.
机译:在丹麦的一个住宅区中,湿度传感器已安装在32栋房屋中,一部分在墙壁上,一部分在屋顶上。墙壁和屋顶用纤维素绝缘材料绝缘,并带有或不带有PE蒸汽屏障。本文描述了两个冬季的湿度测量结果。住宅中还记录了室内气候。结果是,在丹麦条件下,墙壁和屋顶的湿度条件以及室内气候都不取决于是否使用了PE蒸气屏障。