IMPACT OF HIGH H_2S LEVELS ON LANDFILL GAS SYSTEM EXPANSION AND TITLE V PERMITTING AT THE NAPLES LANDFILL

机译:高H_2S水平对那不勒斯填埋场填埋气系统扩展和标题V许可的影响

获取原文
获取原文并翻译 | 示例

摘要

This paper discusses how the high hydrogen sulfide (H_2S) concentration in landfill gas (LFG) at the Naples Landfill affected the permitting and expansion of the LFG collection and control system, and how air pollution modeling was used to avoid Prevention of Significant Deterioration (PSD) permitting requirements and facilitate issuance of the Title V permit modification. To address landfill gas odors, which had become a serious problem at the site, steps were taken to expand the LFG collection and control system, including an upgrade to the landfill gas flare. However, due to a H_2S concentration of 3,600 parts per million by volume (ppmv) coupled with a proposed increase in flow rate to 3,000 standard cubic feet per minute (scfm), potential sulfur dioxide (SO_2) emissions were 468 tons per year (tpy), which was high enough to trigger PSD permitting requirements. The modeling results had two primary consequences. First, in order to avoid fumigation resulting from potential downwash due to air currents near the existing landfill cells, the location of the flare was moved several hundred feet away from the initially proposed location. Another significant result was the need for a non-conventional stack height for the flare in order to increase atmospheric dispersion of the flare emissions in order to not exceed ambient air quality standards.
机译:本文讨论了那不勒斯垃圾填埋场中填埋气(LFG)中高浓度的硫化氢(H_2S)如何影响LFG收集和控制系统的许可和扩展,以及如何使用空气污染模型来避免严重恶化的预防(PSD) )许可要求,并便于签发V头许可修改。为了解决在现场已成为严重问题的垃圾填埋气的气味,已采取措施扩大LFG收集和控制系统,包括升级垃圾填埋气火炬。但是,由于H_2S浓度为百万分之3,600体积(ppmv),并且建议将流速提高至每分钟3,000标准立方英尺(scfm),因此潜在的二氧化硫(SO_2)排放量为每年468吨(tpy ),这足以触发PSD许可要求。建模结果有两个主要结果。首先,为了避免由于现有垃圾填埋场附近的气流导致潜在的向下冲洗而造成的熏蒸,将火炬的位置移离了最初提议的位置几百英尺。另一个显着的结果是,火炬需要非常规的烟囱高度,以增加火炬排放物在大气中的扩散,从而不超过环境空气质量标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号